3.1 Intended use
3 Safety
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
3-8
Please also note the following guidelines in danger zones in areas that
cannot be detected and monitored by the safeguard.
Example: Upper tool with a danger zone outside the zone monitored by
the PSENvip
Fig. 3-3: Danger zone in unmonitored zone
Example: In unmonitored zones, the use of tools which are not fully de-
tected by the protected field on the PSENvip (e.g. tools with a radius
greater than 25 mm) will lead to the risk of fingers or hands being
crushed or trapped!
Fig. 3-4: Crush points when the tool is wider than the protected field