Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
7-19
7.4 Enter overrun
7 Commissioning
7.4Enter overrun7400Enter overrun7-Inbetriebnahme_Nachlaufweg_eingeben_P_Variante_1
The max. overrun is a press brake variable that will depend on the ma-
chine type. Once the closing movement has stopped, the max. overrun
must not be exceeded.
The overrun is entered during configuration via the keypad on the PSEN-
vip receiver.
Funktion_Nachlaufweg_P_Variante
Normally, the factory-assigned overrun is sufficient and does not have
to be configured.
Funktion_Nachlaufweg_Warnung_3
Inbetriebnahme_Nachlaufweg_eingeben_P_Variante_2
To enter the overrun, follow the instructions below:
Switch off the voltage to the PSENvip.
Press the <ESC> + <ENTER> keys and keep them held down.
Switch the supply voltage back on.
Release the <ESC> + <ENTER> keys when Password? appears on
the display.
Enter the password within 10 s.
To do this, press the following keys in the specified sequence: 1. ,
2. , 3. , 4. .
The menu for entering the overrun will appear.
NOTICE
The overrun may only be entered by the press brake manufac-
turer or suitably authorised persons.
WARNING!
If you require a different overrun path than the factory-set path,
then use the value indicated by the manufacturer on the name-
plate of the press brake, or a higher value.
If you enter a lower value for the overrun, the protected field will
also be reduced to an unpermitted level.
Failure to comply could result in a hazardous situation, which
could lead to serious injury and death.
Komentarze do niniejszej Instrukcji