6-1
6.1 General wiring guidelines
6 Wiring
66000WiringWiring6-6.1General wiring guidelines6100General wiring guidelines6-][Verdrahtung BA Einleitung
Please note:
][Verdrahtung ST-Ausgang
The actuators may be connected using unshielded cables.
The outputs do not need suppression for inductive loads.
Use copper wiring.
][Verdrahtung Zusatz mit C
The terminal configuration as stated on the front plate applies for base
modules with C-rail. The terminal configuration as stated in the tech-
nical documentation applies for all other base modules.
6.1.1 Mechanical connection of the base modules
Mechanical connection of the base modules6-][Modulverdrahtung mech
Procedure:
Use a flat blade screwdriver (DIN 5264-A)!
Strip the wire back 8 mm.
If necessary, label the connection level with a colour marker [3].
Base module with screw terminals:
– Use a screwdriver to loosen the screw on the screw terminal [1]
– Insert the stripped cable into the round fixing hole [2], as far as it
will go.
– Tighten up the screw on the screw terminal.
– Check that the cable is firmly seated.
Base module with cage clamp terminals:
– Insert the screwdriver [4] into the square hole [1].
– Insert the stripped cable into the round fixing hole [2], as far as it
will go [5].
– Pull out the screwdriver [6].
– Check that the cable is firmly seated.