8.2 Operating notes
8 Operation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-2
8.2Operating notes8200Operating notes8-
8.2.1 Switch on PSENvip
Switch on PSENvip8-Betrieb_PSENvip_einschalten
The PSENvip is ready for operation once supply voltage has been ap-
plied and the self test has been carried out.
Switch on the supply voltage.
A self-test runs while the start screen is displayed on screen.
An error message will appear if an error is detected.
Fig. 8-1: Display after power-up
8.2.2 Muting lamp
Muting lamp8-Betrieb_Mutinglampe
Muting lamps warn of residual hazards associated with the safeguard.
Betrieb_Mutinglampe_Basis
The muting lamp is lit when
With a full protected field (standard protected field mode), a slow
closing speed is achieved (v <10 mm/s) and the programmable safety
system is muting the OSSDs.
A press stroke is performed while the protected field is reduced.
Betrieb_Mutinglampe_ausserhalb_Gefahrenbereich
INFORMATION
Information on the error that has occurred and how to rectify it
can be found in the chapter entitled "Diagnostics and Trouble-
shooting".
Rectify the error.
If no error has been detected, the display will show the status of
the OSSD and the protected field mode that is currently
selected, which is standard in the example.
SYSTEM OK
OSSD ON
NORMAL OPERATION