Pilz PSENvip RL D P Instrukcja Użytkownika Strona 101

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 100
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-17
7.3 Adjustment during tool change
7 Commissioning
Tool class 2
The contour of these tools is fully detected by the PSENvip.
The front (V2) and rear (H2) bending lines are within the protected
field.
The front segments of the protected field are less than 15 mm away
from the front bending line.
These tools are not safeguarded in compliance with the standards.
Example:
Fig. 7-15: Example for tool class 2
Tool class 3
The contour of these tools is not fully detected by the PSENvip.
The front (V3) and/or rear (H3) bending lines are within the protected
field.
These tools are not safeguarded in compliance with the standards.
Example:
Fig. 7-16: Example for tool class 3
> 25 mm
<15 mm
HV
HV
Przeglądanie stron 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 156 157

Komentarze do niniejszej Instrukcji

Brak uwag