Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
7-1
7.1 Messages
7 Operation
77000OperationOperation7-7.1Messages7100Messages7-Betrieb_Meldungen_allgemein_BA
When the supply voltage is switched on, the PNOZmulti safety system
copies the configuration from the chip card.
The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up
on the base unit.
Betrieb_Meldungen_Modul_Ready_BA
The PNOZmulti safety system is ready for operation when the "POWER"
and "RUN" LEDs on the base unit and the "READY" LED on the PNOZ
ms2p TTL are lit continuously.
7.1.1 Display elements
Display elements7-Anzeige Legende 3x
Key:
7.1.1.1 Display elements for device diagnostics
Display elements for device diagnostics7-Betrieb_An zeige_multi_Drehzahlwaechter_BA
LED on
LED flashes
LED off
LED LED status Meaning
POWER Supply voltage is present
FAULT External fault leading to a safe condition; the fault is at the incremental encoder in-
puts whose LEDs are flashing, e.g. short across the contacts
Internal fault leading to safe condition
SHAFT1
SHAFT2
Encoder or wiring fault
Axis 1 and/or axis 2 are in the normal range (no standstill, no overspeed)
Axis 1 and/or axis 2 signalling standstill
Axis 1 and/or axis 2 signalling overdrive
X12
X22
Incremental encoders on terminals X12 and/or X22 are connected correctly
I10, I11, I20,
I21
Proximity switch on terminal I10, I11, I20, I21 is energised
Komentarze do niniejszej Instrukcji