2-1
2.1 Unit structure
2 Overview
22000OverviewOverview2-2.1Unit structure2100Unit structure2-
2.1.1 Scope of delivery
Scope of delivery2-Lieferumfang_Brck_774639_modul_BA
` Expansion modulePNOZ ma1p
` Jumper 774 639
2.1.2 Unit features
Unit features2-Gerätemerkmale_Verwendung
Using the product PNOZ ma1p:
Verwendung/Bildunterschrift_multi_Modul
Expansion module for connection to a base unit from the PNOZmulti
modular safety system
Geraetemerkmale_Zusatz BA Einleitung
The product has the following features:
Gertemerkmale
` 2 safe analogue inputs for current or voltage measurement (configura-
ble)
` Voltage range: -10,24 ... +10.2375 V
` Current range: 0 ... 25.59 mA
` Resolution
Voltage measurement: 13 Bit (signed 12 Bit)
Current measurement: 12 Bit
` Range monitoring (4 range limits can be configured)
` Threshold value monitoring (8 threshold values can be configured)
` Max. 4 PNOZ ma1p units can be connected to the base unit
` LED indicators for
Operating status
Status of the input signals (Ch0, Ch1)
Errors
Geraetemerkmal_Coated Version
` Coated version:
Increased environmental requirements