Commissioning
OperatingManualPNOZmESCANopen
1002699EN03
16
}
Onlyusemetalplugsormetallisedplasticplugs
}
Twistedpair,screenedcablemustbeusedtoconnecttheinterfaces
6.1.3.1 CANopentermination
Tominimisecablereflectionandtoguaranteeadefinedrestsignalonthetransmissionline,
CANopenmustbeterminatedatbothends.
6.2 Preparingforoperation
6.2.1 Settingthetransmissionrate
1
2
3
4
9
8
7
6
0
5
DR
}
OntheupperrotaryswitchDR,useasmallscrewdrivertosetthetransmissionrate(in
theexample,"3"correspondsto50kBit/s).
Switchsetting 0 1 2 3 4 5 6 7 8 9
Transmissionrate 10
kBit/s
20
kBit/s
50
kBit/s
125
kBit/s
250
kBit/s
500
kBit/s
800
kBit/s
1
MBit/s
INFORMATION
Thetransmissionratecannotbechangedduringoperation.
6.2.2 Settingthestationaddress
ThestationaddressoftheexpansionmodulePNOZmESCANopenissetbetween0...99
(decimal)viatworotaryswitchesx1andx10.